XEROX CORP -- 5R161, 5090/DOCUTECH/4135 DEVELOPER -- 6850-01-323-1528
=====================  Product Identification  =====================

Product ID:5R161, 5090/DOCUTECH/4135 DEVELOPER
MSDS Date:02/18/1992
FSC:6850
NIIN:01-323-1528
=== Responsible Party ===
Company Name:XEROX CORP
Address:100 CLINTON AVE S
City:ROCHESTER
State:NY
ZIP:14644-1877
Country:US
Info Phone Num:800-828-6571
Emergency Phone Num:716-422-2177;716-422-1230
CAGE:0E6G9
=== Contractor Identification ===
Company Name:XEROX CORP
Address:300 MAIN ST NO 27C
City:EAST ROCHESTER
State:NY
ZIP:14645
Country:US
Phone:800-828-6571; 800-351-2024
CAGE:0E6G9
Company Name:XEROX CORPORATION
Address:100 CLINTON AVE SOUTH
Box:City:ROCHESTER
State:NY
ZIP:14644-1877
Country:US
Phone:800-828-6571/716-422-2177
CAGE:26921

=============  Composition/Information on Ingredients  =============

Ingred Name:CARRIER CONSISTING OF INGRED 2.
RTECS #:9999999ZZ
Fraction by Wt: > 95%

Ingred Name:IRON; (STEEL POWDER)
CAS:7439-89-6
RTECS #:NO4565500
Fraction by Wt: > 95%
OSHA PEL:10 MG/M3 AS FE2O3
ACGIH TLV:5 MG/M3

Ingred Name:TONER CONSISTING OF INGREDIENTS 4-7.
RTECS #:9999999ZZ
Fraction by Wt: < 5%

Ingred Name:STYRENE POLYMER WITH 1,3-BUTADIENE; (STYRENE/BUTADIENE
    COPOLYMER)
CAS:9003-55-8
RTECS #:WL6478000
Fraction by Wt: 75-85%

Ingred Name:IRON (III) OXIDE
CAS:1309-37-1
RTECS #:NO7400000
Fraction by Wt: 15-20%
OSHA PEL:10 MG/M3 (FE)
ACGIH TLV:5 MG/M3(FE),B2; 9293

Ingred Name:CARBON BLACK
CAS:1333-86-4
RTECS #:FF5800000
Fraction by Wt: < 5%
OSHA PEL:3.5 MG/M3
ACGIH TLV:3.5 MG/M3

Ingred Name:QUATERNARY AMMONIUM SALT; (QUATERNARY AMMONIUM SALTS)
CAS:123312-54-9
Fraction by Wt: < 2%

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:LD50: (ORAL,RAT) > 10 G/KG
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:MIN RESP TRACT IRRIT MAY OCCUR AS
    W/EXPOS TO LRG AMTS OF ANY NON-TOX DUST. IN A XEROX SPONSORED
    CHRONIC INHAL STUDY IN RATS USING SPECIAL TEST TONER, THERE WERE NO
    LUNG CHANGES @ ALL IN THE LOWEST EXP OS LEVEL (1 MG/M3), THE MOST
    RELEVANT LEVEL TO POTENTIAL HUMAN EXPOS. A VERY SLIGHT DEGREE OF
    FIBROSIS(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:WAS NOTED IN 25% OF THE ANIMALS @ THE
    MIDDLE EXPOS LEVEL (4 MG/M3) WHILE A SLIGHT DEGREE OF FIBROSIS WAS
    OBSERVED AT THE HIGHEST EXPOS LEVEL (16 MG/M3) IN ALL ANIMALS.
    THESE FINDINGS ARE ATTR IBUTED TO "LUNG OVERLOADING" A GENERIC
    RESPONSE TO EXCESS AMTS OF ANY DUST RETAINED IN THE LUNGS FOR A
    PRLNGD(SUPP DATA)
Medical Cond Aggravated by Exposure:NONE WHEN USED AS DESCRIBED BY
    PRODUCT LITERATURE.

=======================  First Aid Measures  =======================

First Aid:EYES: FLUSH WITH WATER FOR AT LEAST 15 MIN. SKIN: WASH WITH
    SOAP AND WATER. INHAL: REMOVE FROM EXPOSURE. INGEST: DILUTE STOMACH
    CONTENTS WITH SEVERAL GLASSES OF WATER.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:WATER, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:AVOID INHALATION OF SMOKE. WEAR NIOSH/MSHA
    APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:IF SPILLED, SWEEP UP OR VACUUM.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:NONE.
Other Precautions:AVOID PROLONGED INHALATION OF EXCESSIVE DUST.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE REQUIRED WHEN USED AS INTENDED IN XEROX
    EQUIPMENT. NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE
    OF CONCERN .
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP: INTERVAL. THE SPECIAL TEST TONER WAS TEN TIMES MORE
    RESPIRABLE THAN COMMERCIALLY AVAILABLE XEROX TONER TO COMPLY WITH
    EPA TESTING PROTOCOL & WOULD NOT FUNCTION PROPERLY IN XEROX EQUIP
    MENT.

==================  Physical/Chemical Properties  ==================

Spec Gravity:5 (H*2O=1)
Appearance and Odor:BLACK GRANULAR/FAINT ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:PRODUCTS OF COMBUSTION MAY BE TOXIC.
    AVOID BREATHING SMOKE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:WHEN DISP, THIS MATL IS NOT A HAZ WASTE ACCORD
    TO FED REG 40 CFR 261. HOWEVER, STATE & LOCAL REQUIREMENTS MAY BE
    MORE RESTRICTIVE. THEREFORE, CONSULTATION WITH THE APPROPRIATE
    FEDERAL, STATE AND LOCAL  WASTE DISPOSAL AUTHORITIES IS ADVISED.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.