XEROX CORP -- 5R161, 5090/DOCUTECH/4135 DEVELOPER -- 6850-01-323-1528
===================== Product Identification ===================== Product ID:5R161, 5090/DOCUTECH/4135 DEVELOPER MSDS Date:02/18/1992 FSC:6850 NIIN:01-323-1528 === Responsible Party === Company Name:XEROX CORP Address:100 CLINTON AVE S City:ROCHESTER State:NY ZIP:14644-1877 Country:US Info Phone Num:800-828-6571 Emergency Phone Num:716-422-2177;716-422-1230 CAGE:0E6G9 === Contractor Identification === Company Name:XEROX CORP Address:300 MAIN ST NO 27C City:EAST ROCHESTER State:NY ZIP:14645 Country:US Phone:800-828-6571; 800-351-2024 CAGE:0E6G9 Company Name:XEROX CORPORATION Address:100 CLINTON AVE SOUTH Box:City:ROCHESTER State:NY ZIP:14644-1877 Country:US Phone:800-828-6571/716-422-2177 CAGE:26921 ============= Composition/Information on Ingredients ============= Ingred Name:CARRIER CONSISTING OF INGRED 2. RTECS #:9999999ZZ Fraction by Wt: > 95% Ingred Name:IRON; (STEEL POWDER) CAS:7439-89-6 RTECS #:NO4565500 Fraction by Wt: > 95% OSHA PEL:10 MG/M3 AS FE2O3 ACGIH TLV:5 MG/M3 Ingred Name:TONER CONSISTING OF INGREDIENTS 4-7. RTECS #:9999999ZZ Fraction by Wt: < 5% Ingred Name:STYRENE POLYMER WITH 1,3-BUTADIENE; (STYRENE/BUTADIENE COPOLYMER) CAS:9003-55-8 RTECS #:WL6478000 Fraction by Wt: 75-85% Ingred Name:IRON (III) OXIDE CAS:1309-37-1 RTECS #:NO7400000 Fraction by Wt: 15-20% OSHA PEL:10 MG/M3 (FE) ACGIH TLV:5 MG/M3(FE),B2; 9293 Ingred Name:CARBON BLACK CAS:1333-86-4 RTECS #:FF5800000 Fraction by Wt: < 5% OSHA PEL:3.5 MG/M3 ACGIH TLV:3.5 MG/M3 Ingred Name:QUATERNARY AMMONIUM SALT; (QUATERNARY AMMONIUM SALTS) CAS:123312-54-9 Fraction by Wt: < 2% ===================== Hazards Identification ===================== LD50 LC50 Mixture:LD50: (ORAL,RAT) > 10 G/KG Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:MIN RESP TRACT IRRIT MAY OCCUR AS W/EXPOS TO LRG AMTS OF ANY NON-TOX DUST. IN A XEROX SPONSORED CHRONIC INHAL STUDY IN RATS USING SPECIAL TEST TONER, THERE WERE NO LUNG CHANGES @ ALL IN THE LOWEST EXP OS LEVEL (1 MG/M3), THE MOST RELEVANT LEVEL TO POTENTIAL HUMAN EXPOS. A VERY SLIGHT DEGREE OF FIBROSIS(EFTS OF OVEREXP) Explanation of Carcinogenicity:NOT RELEVANT Effects of Overexposure:HLTH HAZ:WAS NOTED IN 25% OF THE ANIMALS @ THE MIDDLE EXPOS LEVEL (4 MG/M3) WHILE A SLIGHT DEGREE OF FIBROSIS WAS OBSERVED AT THE HIGHEST EXPOS LEVEL (16 MG/M3) IN ALL ANIMALS. THESE FINDINGS ARE ATTR IBUTED TO "LUNG OVERLOADING" A GENERIC RESPONSE TO EXCESS AMTS OF ANY DUST RETAINED IN THE LUNGS FOR A PRLNGD(SUPP DATA) Medical Cond Aggravated by Exposure:NONE WHEN USED AS DESCRIBED BY PRODUCT LITERATURE. ======================= First Aid Measures ======================= First Aid:EYES: FLUSH WITH WATER FOR AT LEAST 15 MIN. SKIN: WASH WITH SOAP AND WATER. INHAL: REMOVE FROM EXPOSURE. INGEST: DILUTE STOMACH CONTENTS WITH SEVERAL GLASSES OF WATER. ===================== Fire Fighting Measures ===================== Extinguishing Media:WATER, FOAM, DRY CHEMICAL. Fire Fighting Procedures:AVOID INHALATION OF SMOKE. WEAR NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT . Unusual Fire/Explosion Hazard:NONE. ================== Accidental Release Measures ================== Spill Release Procedures:IF SPILLED, SWEEP UP OR VACUUM. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:NONE. Other Precautions:AVOID PROLONGED INHALATION OF EXCESSIVE DUST. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:NONE REQUIRED WHEN USED AS INTENDED IN XEROX EQUIPMENT. NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN . Ventilation:NONE SPECIFIED BY MANUFACTURER. Protective Gloves:IMPERVIOUS GLOVES . Eye Protection:CHEMICAL WORKERS GOGGLES . Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER. Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER. Supplemental Safety and Health EFTS OF OVEREXP: INTERVAL. THE SPECIAL TEST TONER WAS TEN TIMES MORE RESPIRABLE THAN COMMERCIALLY AVAILABLE XEROX TONER TO COMPLY WITH EPA TESTING PROTOCOL & WOULD NOT FUNCTION PROPERLY IN XEROX EQUIP MENT. ================== Physical/Chemical Properties ================== Spec Gravity:5 (H*2O=1) Appearance and Odor:BLACK GRANULAR/FAINT ODOR. ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES NONE Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER. Hazardous Decomposition Products:PRODUCTS OF COMBUSTION MAY BE TOXIC. AVOID BREATHING SMOKE. ==================== Disposal Considerations ==================== Waste Disposal Methods:WHEN DISP, THIS MATL IS NOT A HAZ WASTE ACCORD TO FED REG 40 CFR 261. HOWEVER, STATE & LOCAL REQUIREMENTS MAY BE MORE RESTRICTIVE. THEREFORE, CONSULTATION WITH THE APPROPRIATE FEDERAL, STATE AND LOCAL WASTE DISPOSAL AUTHORITIES IS ADVISED. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.