ALUMINUM COMPANY OF AMERICA -- MAGNESIUM RIBBON -- -
=====================  Product Identification  =====================

Product ID:MAGNESIUM RIBBON
MSDS Date:08/31/1992
FSC:NIIN:Submitter:D DG
=== Responsible Party ===
Company Name:ALUMINUM COMPANY OF AMERICA
Address:1501 ALCOA BUILDING
City:PITTSBURGH
State:PA
ZIP:15219
Country:US
Info Phone Num:412-553-4001
Emergency Phone Num:412-553-4001/412-553-4649(TECHNICAL
Preparer's Name:NOT PROVIDED.
Chemtrec Ind/Phone:(800)424-9300
CAGE:TO464
=== Contractor Identification ===
Company Name:ALUMINUM COMPANY OF AMERICA
Address:1501 ALCOA BUILDING
Box:City:PITTSBURGH
State:PA
ZIP:15219
Country:US
Phone:412-553-4001
CAGE:TO464
Company Name:CHEM SCIENTIFIC INC
Address:1250 WASHINGTON ST
Box:City:NORWOOD
State:MA
ZIP:02062
Country:US
Phone:781-440-0900
Contract Num:MDA414-00-P-0959
CAGE:0X801
Company Name:CHEM SCIENTIFIC INC
Address:1250 WASHINGTON ST
Box:City:NORWOOD
State:MA
ZIP:02062
Country:US
Phone:781-440-0900
Contract Num:MDA414-00-P-0962
CAGE:0X801
Company Name:CHEM SCIENTIFIC INC
Address:1250 WASHINGTON ST
Box:City:NORWOOD
State:MA
ZIP:02062
Country:US
Phone:781-440-0900
Contract Num:MDA414-00-P-4747
CAGE:0X801
Company Name:CHEM SCIENTIFIC INC
Address:1250 WASHINGTON ST
Box:City:NORWOOD
State:MA
ZIP:02062
Country:US
Phone:781-440-0900
Contract Num:MDA414-98-P-6953
CAGE:0X801
Company Name:CHEM SCIENTIFIC INC
Address:1250 WASHINGTON ST
Box:City:NORWOOD
State:MA
ZIP:02062
Country:US
Phone:781-440-0900
Contract Num:MDA414-99-P-3288
CAGE:0X801
Company Name:CHEM SCIENTIFIC, LLC
Address:67 CHAPEL STREET
Box:UNK
City:NEWTON
State:MA
ZIP:02158
Country:US
Phone:617-527-6626
CAGE:TO442
Company Name:NASCO INTL INC., NASCO DIV
Address:901 JANESVILL AVE
Box:City:FORT ATKINSON
State:WI
ZIP:53538-0901
Country:US
Phone:920-563-2446
Contract Num:MDA414-99-A-0001-0253
CAGE:33089
Company Name:NASCO INTL INC., NASCO DIV
Address:901 JANESVILL AVE
Box:City:FORT ATKINSON
State:WI
ZIP:53538-0901
Country:US
Phone:920-563-2446
Contract Num:MDA414-99-A-0007-0153
CAGE:33089
Company Name:WARDS NATURAL SCIENCE ESTABLISHMENT INC
Address:5100 W HENRIETTA RD
Box:92912
City:ROCHESTER
State:NY
ZIP:14692-9012
Country:US
Phone:(716) 359-2502
Contract Num:MDA414-99-A-0024-0039
CAGE:63759
Company Name:WARDS NATURAL SCIENCE ESTABLISHMENT INC
Address:5100 W HENRIETTA RD
Box:92912
City:ROCHESTER
State:NY
ZIP:14692-9012
Country:US
Phone:(716) 359-2502
Contract Num:MDA414-99-P-4866
CAGE:63759

=============  Composition/Information on Ingredients  =============

Ingred Name:MAGNESIUM METAL
CAS:7439-95-4
RTECS #:OM2100000
= Wt:99.8
Other REC Limits:NOT PROVIDED.
OSHA PEL:10 MG/M3 MGO FUME
ACGIH TLV:10 MG/M3 MGO FUME

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NO DATA PROVIDED BY RESPONSIBLE PARTY.
Health Hazards Acute and Chronic:EXPOSURE TO MAGNESIUM METAL OR OXIDE
    DUST SHOULD BE A LOW HEALTH RISK BY INHALATION AND SHOULD BE
    TREATED AS A NUISANCE DUST. EXPOSURE TO MAGNESIUM OXIDE FUME
    SUBSEQUENT TO BURNING, WELDING, MOLTEN ME TAL WORK, ETC. CAN RESULT
    IN METAL FUMEFEVER. TEMPORARY SYMPTOMS CAN INCLUDE FEVER, CHILLS,
    NAUSEA, VOMITING, AND MUSCULAR PAIN. ONSET OF SYMTPOMS OCCURS 4-12
    HOURS AFTER EXPOSURE. RECOVERY IS USUALLY  COMPLETE IN 24-48 HOURS.
    MEETING THE EXPOSURE LIMITS OF 10 MG/M3 MGO FUME, 5 MG/M3
    (RESPIRABLE) SHOULD PREVENT METAL FUME FEVER FROM OCCURING.
Explanation of Carcinogenicity:NO DATA PROVIDED BY RESPONSIBLE PARTY.
Effects of Overexposure:EXPOSURE TO MAGNESIUM OXIDE FUME CAN RESULT IN
    FEVER, CHILLS, NAUSEA, VOMITING, AND MUSCULAR PAIN.
Medical Cond Aggravated by Exposure:NO DATA PROVIDED BY RESPONSIBLE
    PARTY.

=======================  First Aid Measures  =======================

First Aid:NO DATA PROVIDED BY RESPONSIBLE PARTY.

=====================  Fire Fighting Measures  =====================

Flash Point:NONE.
Autoignition Temp:=510.C, 950.F
Extinguishing Media:SMOTHER FIRE WITH DRY GRAPHITE/OTHER SUITABLE DRY
    POWDERS. DO NOT USE FOAM, HALOGENATED EXTINGUISHING AGENTS OR
    CARBON DIOXIDE. PREVENT WATER OF CONTACTING BURNING/MOLTEN
    MAGESIUM.
Fire Fighting Procedures:FIREFIGHTERS SHOULD WEAR NIOSH APPROVED
    SELF-CONTAINED BREATHING APPARATUS (SCBA) AND PROTECTIVE CLOTHING
    WHEN APPROPRIATE. PROTECT EYES AND SKIN AGAINST FLYING PARTICLES.
    MANUAL APPLICATION OF WATER  SHOULD BE CONDUCTED WITH CARE TO
    PREVENT CONTACT WITH BURNING OR MOLTEN MAGNESIUM.
Unusual Fire/Explosion Hazard:FINE POWDER, THIN SHEETS, CHIPS, AND
    TURNINGS ARE EASILY IGNITED AND BURN WITH INTENSE HEAT AND
    BRILLIANT WHITE FLAME. POWDERS MAY FORM EXPLOSIVE MIXTURES WITH
    AIR. MOLTEN METAL MAY REACT VIOLENTLY ON  CONTACT WITH WATER.

==================  Accidental Release Measures  ==================

Spill Release Procedures:COLLECT SCRAP IN CONTAINERS FOR REMELTING.
Neutralizing Agent:NO DATA PROVIDED BY RESPONSIBLE PARTY.

======================	Handling and Storage  ======================

Handling and Storage Precautions:PROTECT CONTAINERS AGAINST PHYSICAL
    DAMAGE. WET, MOIST OR HIGH HUMIDITY STORAGE CONDITIONS  WILL LEAD
    TO CORROSION OF THE PRODUCT. STORE AWAY FROM OTHER COMBUSTIBLES IN
    METAL CABINET. SCRAP SHOULD BE  KEPT DRY PRIOR TO REMELTING
    OPERATIONS.
Other Precautions:NO DATA PROVIDED BY RESPONSIBLE PARTY.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:WHERE THE EXPOSURE LIMIT IS OR MAY BE EXCEEDED,
    USE NIOSH APPROVED RESPIRATORY PROTECTION. THE SELECTION OF
    APPROPRIATE RESPIRATOR (DUST AND FUME RESPIRATOR, ETC.) SHOULD BE
    BASED ON THE ACTUAL OR POT ENTIAL AIRBORNE CONTAMINANTS AND THEIR
    CONCENTRATIONS PRESENT.
Ventilation:USE WITH ADEQUATE VENTILATION TO MEET EXPOSURE LIMITS.
Protective Gloves:FIRE RESISTANT.
Eye Protection:APPROPRITE EYE PROTECTION AS NECESSARY.
Other Protective Equipment:WEAR APPROPRIATE FIRE-RESISTANT CLOTHING
    (GLOVES, COVERALLS) WHEN EXPOSING MAGNESIUM RIBBON TO ELEVATED
    TEMPERATURES (950F) WHICH CAN CAUSE IGNITION.
Work Hygienic Practices:NO DATA PROVIDED BY RESPONSIBLE PARTY.
Supplemental Safety and Health
VENDORS P/N: M5-1 OZ. MAGNESIUM METAL RIBBON.

==================  Physical/Chemical Properties  ==================

HCC:F8
Boiling Pt:=1110.C, 2030.F
Melt/Freeze Pt:=650.C, ######F
Decomp Temp:Decomp Text:NOT PROVIDED.
Vapor Pres:NOT APPLICABLE.
Spec Gravity:1.74, DENSITY:0.063LB/IN3
pH:NOT APPLICABLE.
Viscosity:NOT APPLICABLE.
Evaporation Rate & Reference:NOT APPLICABLE.
Solubility in Water:NEGLIGIBLE
Appearance and Odor:SILVERY/WHITE COLOR SOLID METAL RIBBON, 0.006"
    THICK BY 1/8" WIDE, NO ODOR.
Corrosion Rate:NOT PROVIDED.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
MAGNESIUM WILL REACT WITH WATER AND ACIDS TO RELEASE HYDROGEN; ALSO
    HAZARDOUS WITH  CHLORINE, BROMINE, IODINE, OXIDIZING AGENTS, AND
    ACIDS.
Stability Condition to Avoid:AVOID EXPOSURE TO MOISTURE, HEAT, SPARKS,
    FLAME.
Hazardous Decomposition Products:NO DATA PROVIDED BY RESPONSIBLE PARTY.

===================  Toxicological Information	===================

Toxicological Information:NO DATA PROVIDED BY RESPONSIBLE PARTY.

=====================  Ecological Information  =====================

Ecological:NO DATA PROVIDED BY RESPONSIBLE PARTY.

====================  Disposal Considerations  ====================

Waste Disposal Methods:RCRA HAZARDOUS WASTE NO.: NOT FEDERALLY
    REGULATED.

===================  MSDS Transport Information  ===================

Transport Information:D.O.T SHIPPING NAME, HAZARD CLASS, I.D. NO.:
    MAGNESIUM METAL (RIBBON), FLAMMABLE SOLID, UN 1869.

=====================  Regulatory Information  =====================

SARA Title III Information:FOR PURPOSES OF SARA III REPORTING, THIS
    SUBSTANCE CONTAINS NO INGREDIENTS LISTED ON THE EXTREMELY
    HAZARDOUS, OR 313 LISTS. FOR PURPOSES OF CERCLA REPORTING, THIS
    SUBSTANCE CONTAINS NO LISTED INGREDIE NTS. THIS MATERIAL FITS THE
    EPA HAZARD CATEGORY DEFINITION OF A FIRE HAZARD UNDER SARA SECTION
    311, 312. IF FUMES ARE GENERATED DURING PROCESSING, THIS MATERIAL
    FITS THE EPA HAZARD CATEGORY OF IMMEDIA TE (ACUTE) HEALTH HAZARD
    UNDER SARA SECTIONS 311, 312. IF MOLTEN, THIS MATERIAL FITS THE EPA
    HAZARD CATEGORY OF REACTIVE HAZARD UNDER SARA SECTIONS 311, 312.
Federal Regulatory Information:COMPONENTS OF THIS PRODUCT ARE LISTED ON
    THE TSCA INVENTORY.
State Regulatory Information:NO DATA PROVIDED BY RESPONSIBLE PARTY.

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.