ANSUL FIRE PROTECTION -- CARBON DIOXIDE -- 6830-01-377-0074
===================== Product Identification ===================== Product ID:CARBON DIOXIDE MSDS Date:01/25/1993 FSC:6830 NIIN:01-377-0074 === Responsible Party === Company Name:ANSUL FIRE PROTECTION Address:1 STANTON ST City:MARINETTE State:WI ZIP:54143-2542 Country:US Info Phone Num:715-735-7411 Emergency Phone Num:800-424-9300(CHEMTREC) CAGE:03670 === Contractor Identification === Company Name:ANSUL INC Address:ONE STANTON STREET Box:City:MARINETTE State:WI ZIP:54143-2542 Country:US Phone:715-735-7411 CAGE:03670 ============= Composition/Information on Ingredients ============= Ingred Name:CARBON DIOXIDE CAS:124-38-9 RTECS #:FF6400000 Fraction by Wt: 100% OSHA PEL:5000 PPM ACGIH TLV:5000 PPM ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:SKIN:EVAPORATION OF LIQ CAN PRDCE CHILLING SENSATIONS. FROSTBITE CAN OCCUR. AVOID CO*2 SNOW (DRY ICE). INHAL:VAP IS HVR THAN AIR & CAN CAUSE SUFFOCATION BY REDUCING OXYG AVAIL FOR BRTHG. BRTHG VERY HI GH CONCS OF VAP CAN CAUSE LIGHTHEADEDNESS, GIDD, SHORTNESS OF BRTH, MUSCULAR TREMORS & WEAK, (EFTS OF OVEREXPOS) Explanation of Carcinogenicity:NOT RELEVANT Effects of Overexposure:HLTH HAZS:ACROCYANOSIS. ALSO UNCONSCIOUSNESS OR EVEN DEATH. CAN CAUSE DIZZ, IMPAIRED COORD, REDUCED MENTAL ACUITY, HDCHS, TINNITUS, DFCLTY BRTHG, DROW, DEPENDING ON LENGTH OF EXPOS & CONCS. CHRONIC:NO NE KNOWN WHEN OCCUPATIONAL EXPOSURES ARE BELOW THE TLV. Medical Cond Aggravated by Exposure:RESPIRATORY PROBLEMS. ======================= First Aid Measures ======================= First Aid:INGEST:CALL MD IMMEDIATELY . EYES:IMMED FLUSH W/PLENTY OF WATER FOR @ LST 15 MIN WHILE HOLDING LIDS OPEN. IF REDNESS ITCHING/BURNING SENSATION DEVELOPS, GET MED ATTN. TREAT FOR FROSTBITE IF NEC. SKIN:WASH W/COPIOUS AMTS OF SOAP & WATER FOR @ LST 15 MIN. IF REDNESS, ITCHING/BURNING SENSATION DEVELOPS, GET MED ATTN. TREAT FOR FROSTBITE IF NEC. INHAL:REMOVE TO FRESH AIR, IF COUGH/OTHER (SUPDAT) ===================== Fire Fighting Measures ===================== Flash Point:NONE Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE . Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE EQUIPMENT . NONE-THIS IS AN EXTINGUISHING AGENT. Unusual Fire/Explosion Hazard:THOUGH GAS CYLINDERS ARE EQUIPPED WITH PRESSURE AND TEMPERATURE RELIEF DEVICES, THEY SHOULD BE REMOVED FROM HIGH TEMPERATURES OR FIRE TO AVOID RISK OF RUPTURE. ================== Accidental Release Measures ================== Spill Release Procedures:EVACUATE AREA: VENTILATE TO OUTSIDE ATMOSPHERE. COOL OR REMOVE HOT, METAL SURFACES OR SOURCE OF NON-EXTINGUISHING FLAMES. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:STORE CONTAINERS IN A CLEAN, DRY, WELL-VENTILATED AREA, AWAY FROM HEAT >120F. STORE AS A COMPRESSED GAS IN DOT APPROVED VESSELS. Other Precautions:IF CYLINDER OR CARTRIDGE IS NOT ATTACHED TO A SYSTEM, IT MUST BE SAFETY CAPPED TO PROTECT AGAINST VIOLENT VESSEL MOVEMENT OR FORCE OF ESCAPING GAS IF VALVE IS ACTUATED OR SEAL PUNCTURED. SEE INFORMATI ON IN MATERIALS TO AVOID. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:NOT NORMALLY NECESSARY IF CONTROLS ARE ADEQUATE. IF TLV IS EXCEEDED OR IF EXPOSURE IS PROLONGED, A NIOSH/MSHA APPROVED SELF-CONTAINED BREATHING APPARATUS IS RECOMMENDED. Ventilation:LOCAL EXHAUST:RECOMMENDED IN CONFINED SPACES. MECHANICAL (GENERAL):RECOMMENDED. Protective Gloves:IMPERVIOUS GLOVES . Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT) Other Protective Equipment:EMERGENCY EYE WASH & DELUGE SHOWER WHICH MEET ANSI DESIGN CRITERIA . PROTECTIVE CLOTHING FOR CONTACT WITH DRY ICE. Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER. Supplemental Safety and Health SOL IN H*2O:88 ML CO*2 PER 100 ML H*2O @ 20C. FIRST AID PROC:RESP SYMPS OCCUR, CONSULT MED PERS. IF NOT BRTHG, GIVE ARTF RESP, PREFERABLY MOUTH-TO-MOUTH. IF BRTHG IS DFCLT, GIVE OXYG. CONSULT MED PERS . EYE PROT:AND FULL LENGTH FACE SHIELD . ================== Physical/Chemical Properties ================== Vapor Pres:830PSI@20C Vapor Density:1.5 Spec Gravity:1.98 (H*2O=1) Solubility in Water:SUPP DATA Appearance and Odor:COLORLESS GAS WITH NO ODOR. Percent Volatiles by Volume:100 ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES REACTS VIGOROUSLY WITH (AL + NA*2O*2), CS*2O, LI, K, MG (C*2H*5)2, (MG + NA*2O), KHC*2, NA, NA*2C*2, NAK, TI. Hazardous Decomposition Products:NONE ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPOSE OF IN COMPLIANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.