ANSUL FIRE PROTECTION -- CARBON DIOXIDE -- 6830-01-377-0074
=====================  Product Identification  =====================

Product ID:CARBON DIOXIDE
MSDS Date:01/25/1993
FSC:6830
NIIN:01-377-0074
=== Responsible Party ===
Company Name:ANSUL FIRE PROTECTION
Address:1 STANTON ST
City:MARINETTE
State:WI
ZIP:54143-2542
Country:US
Info Phone Num:715-735-7411
Emergency Phone Num:800-424-9300(CHEMTREC)
CAGE:03670
=== Contractor Identification ===
Company Name:ANSUL INC
Address:ONE STANTON STREET
Box:City:MARINETTE
State:WI
ZIP:54143-2542
Country:US
Phone:715-735-7411
CAGE:03670

=============  Composition/Information on Ingredients  =============

Ingred Name:CARBON DIOXIDE
CAS:124-38-9
RTECS #:FF6400000
Fraction by Wt: 100%
OSHA PEL:5000 PPM
ACGIH TLV:5000 PPM

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:SKIN:EVAPORATION OF LIQ CAN PRDCE
    CHILLING SENSATIONS. FROSTBITE CAN OCCUR. AVOID CO*2 SNOW (DRY
    ICE). INHAL:VAP IS HVR THAN AIR & CAN CAUSE SUFFOCATION BY REDUCING
    OXYG AVAIL FOR BRTHG. BRTHG VERY HI GH CONCS OF VAP CAN CAUSE
    LIGHTHEADEDNESS, GIDD, SHORTNESS OF BRTH, MUSCULAR TREMORS & WEAK,
    (EFTS OF OVEREXPOS)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS:ACROCYANOSIS. ALSO UNCONSCIOUSNESS OR
    EVEN DEATH. CAN CAUSE DIZZ, IMPAIRED COORD, REDUCED MENTAL ACUITY,
    HDCHS, TINNITUS, DFCLTY BRTHG, DROW, DEPENDING ON LENGTH OF EXPOS &
    CONCS. CHRONIC:NO NE KNOWN WHEN OCCUPATIONAL EXPOSURES ARE BELOW
    THE TLV.
Medical Cond Aggravated by Exposure:RESPIRATORY PROBLEMS.

=======================  First Aid Measures  =======================

First Aid:INGEST:CALL MD IMMEDIATELY . EYES:IMMED FLUSH W/PLENTY OF
    WATER FOR @ LST 15 MIN WHILE HOLDING LIDS OPEN. IF REDNESS
    ITCHING/BURNING SENSATION DEVELOPS, GET MED ATTN. TREAT FOR
    FROSTBITE IF NEC.  SKIN:WASH W/COPIOUS AMTS OF SOAP & WATER FOR @
    LST 15 MIN. IF REDNESS, ITCHING/BURNING SENSATION DEVELOPS, GET MED
    ATTN. TREAT FOR FROSTBITE IF NEC. INHAL:REMOVE TO FRESH AIR, IF
    COUGH/OTHER (SUPDAT)

=====================  Fire Fighting Measures  =====================

Flash Point:NONE
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
    PROTECTIVE EQUIPMENT . NONE-THIS IS AN EXTINGUISHING AGENT.
Unusual Fire/Explosion Hazard:THOUGH GAS CYLINDERS ARE EQUIPPED WITH
    PRESSURE AND TEMPERATURE RELIEF DEVICES, THEY SHOULD BE REMOVED
    FROM HIGH TEMPERATURES OR FIRE TO AVOID RISK OF RUPTURE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:EVACUATE AREA: VENTILATE TO OUTSIDE
    ATMOSPHERE. COOL OR REMOVE HOT, METAL SURFACES OR SOURCE OF
    NON-EXTINGUISHING FLAMES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE CONTAINERS IN A CLEAN, DRY,
    WELL-VENTILATED AREA, AWAY FROM HEAT >120F. STORE AS A COMPRESSED
    GAS IN DOT APPROVED VESSELS.
Other Precautions:IF CYLINDER OR CARTRIDGE IS NOT ATTACHED TO A SYSTEM,
    IT MUST BE SAFETY CAPPED TO PROTECT AGAINST VIOLENT VESSEL MOVEMENT
    OR FORCE OF ESCAPING GAS IF VALVE IS ACTUATED OR SEAL PUNCTURED.
    SEE INFORMATI ON IN MATERIALS TO AVOID.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NOT NORMALLY NECESSARY IF CONTROLS ARE ADEQUATE.
    IF TLV IS EXCEEDED OR IF EXPOSURE IS PROLONGED, A NIOSH/MSHA
    APPROVED SELF-CONTAINED BREATHING APPARATUS IS RECOMMENDED.
Ventilation:LOCAL EXHAUST:RECOMMENDED IN CONFINED SPACES. MECHANICAL
    (GENERAL):RECOMMENDED.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT)
Other Protective Equipment:EMERGENCY EYE WASH & DELUGE SHOWER WHICH
    MEET ANSI DESIGN CRITERIA . PROTECTIVE CLOTHING FOR CONTACT WITH
    DRY ICE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SOL IN H*2O:88 ML CO*2 PER 100 ML H*2O @ 20C. FIRST AID PROC:RESP SYMPS
    OCCUR, CONSULT MED PERS. IF NOT BRTHG, GIVE ARTF RESP, PREFERABLY
    MOUTH-TO-MOUTH. IF BRTHG IS DFCLT, GIVE OXYG. CONSULT MED PERS .
    EYE PROT:AND FULL LENGTH FACE SHIELD .

==================  Physical/Chemical Properties  ==================

Vapor Pres:830PSI@20C
Vapor Density:1.5
Spec Gravity:1.98 (H*2O=1)
Solubility in Water:SUPP DATA
Appearance and Odor:COLORLESS GAS WITH NO ODOR.
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
REACTS VIGOROUSLY WITH (AL + NA*2O*2), CS*2O, LI, K, MG (C*2H*5)2, (MG
    + NA*2O), KHC*2, NA, NA*2C*2, NAK, TI.
Hazardous Decomposition Products:NONE

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN COMPLIANCE WITH LOCAL, STATE AND
    FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.