ZYNOLYTE PRODUCTS INC -- SPEED-E-NAMEL -- 8010-00N006431
=====================  Product Identification  =====================

Product ID:SPEED-E-NAMEL
MSDS Date:08/18/1986
FSC:8010
NIIN:00N006431
=== Responsible Party ===
Company Name:ZYNOLYTE PRODUCTS INC
Address:2320 E DOMINGUEZ ST
City:CARSON
State:CA
ZIP:90749
Country:US
Info Phone Num:213-513-0700
Emergency Phone Num:800-424-9300 (CHEMTREC)
CAGE:25461
=== Contractor Identification ===
Company Name:ZYNOLYTE PRODUCTS CO
Address:2320 E DOMINGUEZ ST
Box:6244
City:CARSON
State:CA
ZIP:90749
Country:US
Phone:310-513-0700
CAGE:25461

=============  Composition/Information on Ingredients  =============

Ingred Name:ALIPHATIC HYDROCARBON (SOLVENT)
Fraction by Wt: 5-20%
OSHA PEL:N/K 
ACGIH TLV:500 PPM (MFR)

Ingred Name:AROMATIC HYDROCARBON SOLVENT
Fraction by Wt: 0-9%
OSHA PEL:N/K 
ACGIH TLV:200 PPM (MFR)

Ingred Name:METHANE, DICHLORO-; (METHYLENE CHLORIDE) (SARA 313)
    (CERCLA)
CAS:75-09-2
RTECS #:PA8050000
Fraction by Wt: 30-45%
OSHA PEL:500 PPM; Z-2
ACGIH TLV:50 PPM, A2
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:PROPELLANT CONTAINING ING 5 & 6
RTECS #:9999999ZZ
Fraction by Wt: 25-35%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:PROPANE, 2-METHYL; (ISOBUTANE)
CAS:75-28-5
RTECS #:TZ4300000
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:PROPANE
CAS:74-98-6
RTECS #:TX2275000
OSHA PEL:1000 PPM
ACGIH TLV:ASPHYXIANT

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:NO
Health Hazards Acute and Chronic:CHLOROCARBON MATLS HAVE PRDCED SENSIT
    OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE A SIMILAR
    EFT IN HUMANS. ADRENOMIMETICS (E.G. EPINEPHRINE) MAY BE
    CONTRAINDICATED EXCEPT FOR LIFE-SUSTAIN ING USES IN HUMANS ACUTELY
    OR CHRONICALLY EXPOSED TO CHLOROCARBONS . ACUTE:ANESTHETIC.
Explanation of Carcinogenicity:METHYLENE CHLORIDE:IARC MONO SUPP, VOL
    7, PG 194, 1987:GROUP 2B. NTP 7TH ANNUAL RPT ON CARCIN, 1994:ANTIC
    TO BE (SUPDAT)
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INGEST:CALL MD IMMEDIATELY . SKIN:FLUSH W/COPIOUS AMOUNTS OF
    WATER. CALL MD. . INHAL:REMOVE FROM AREA. CALL DR. EYES:FLUSH WITH
    LARGE QUANTITIES OF CLEAR WATER FOR @ LEAST 15 MINUTES, TAKE  TO
    PHYS.

=====================  Fire Fighting Measures  =====================

Flash Point:<20F,<-7C
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
    & FULL PROTECTIVE EQUIPMENT . KEEP COOL WITH WATER SPRAY. REMOVE
    FROM FIRE AREA IF POSSIBLE.
Unusual Fire/Explosion Hazard:THERM DECOMP PRODS MAY INCL HCL &
    PHOSGENE . PRESSURIZED PROD. MUST BE STORED @ TEMP BELOW 120F. DO
    NOT STORE NEAR HEAT, SPARKS/OPEN FLAME. (SUPDAT)

==================  Accidental Release Measures  ==================

Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DO NOT STORE ABOVE 120 DEGREES F. DO
    NOT PUNCTURE OR INCINERATE.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GEN VICINITY
    OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT &/OR UV RADIA MAY
    CAUSE FORMATION OF HCL &/OR PHOSGENE .

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE IN WELL VENTILATED AREA. NIOSH/MSHA APPROVED
    RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORK GOGGLES .
Other Protective Equipment:EYE WASH FOUNTAIN AND DELUGE SHOWER MEETING
    ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLO HAZ:EXPOSURE TO HEAT MAY CAUSE BURSTING. DO NOT PUNCTURE/INCIN
    (BURN). USE IN WELL VENTILATED AREA. EXPLAN OF CARCIN:CARCIN.
    ANIMAL:LUNG, LIV, SALIVARY, MAMARY GLAND (TUMORS).

==================  Physical/Chemical Properties  ==================

Vapor Density:HVR/AIR
Spec Gravity:0.79-1.02
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:NOT KNOWN
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:80-95

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:STORAGE ABOVE 120 DEGREES F.
Hazardous Decomposition Products:HCL & PHOSGENE .

====================  Disposal Considerations  ====================

Waste Disposal Methods:FULL OR EMPTY CONTAINERS SHOULD NOT BE PUNCTURED
    OR INCINERATED. DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL, STATE,
    AND LOCAL REGULATIONS .

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.