ZEE MEDICAL INC -- EYE WASH, 605 -- 6505-00N072932
=====================  Product Identification  =====================

Product ID:EYE WASH, 605
MSDS Date:01/01/1993
FSC:6505
NIIN:00N072932
=== Responsible Party ===
Company Name:ZEE MEDICAL INC
Address:22 CORPORATE PARK
City:IRVINE
State:CA
ZIP:92714
Country:US
Info Phone Num:714-252-9500
Emergency Phone Num:714-252-9500
CAGE:EO366
=== Contractor Identification ===
Company Name:ZEE MEDICAL INC
Address:22 CORPORATE PARK
Box:City:IRVINE
State:CA
ZIP:91714
Country:US
Phone:714-252-9500
CAGE:EO366
Company Name:ZEE MEDICAL, INC
Address:22 CORPORATE PARK
Box:City:IRVINE
State:CA
ZIP:92606
Country:US
Phone:714/252-9500
CAGE:6P489

=============  Composition/Information on Ingredients  =============

Ingred Name:AMMONIUM, ALKYLDIMETHYLBENZYL-, CHLORIDE; (BENZALKONIUM
    CHLORIDE)
CAS:8001-54-5
RTECS #:BO3150000
Fraction by Wt: 0.01%
OSHA PEL:N/K 
ACGIH TLV:N/K 

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:LD50 (ORAL FROGS): 30 MG/KG.
Routes of Entry: Inhalation:NO	Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INGESTION OF LARGE QUANTITIES MAY
    CAUSE GASTRIC DISTURBANCES.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INHALATION:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE
    O*2/ARTF RESP) . EYES:IMMEDIATELY FLUSH W/POTABLE WATER FOR A
    MINIMUM OF 15 MINUTES, SEEK ASSISTANCE FROM MD . SKIN:FLUSH
    W/COPIOUS  AMOUNTS OF WATER. CALL MD . INGESTION:IF A LARGE
    QUANTITY HAS BEEN INGESTED, CONTACT A PHYSICIAN IMMEDIATELY.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:COVER WITH ABSORBENT MATERIAL, COLLECT IN
    SUITABLE CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:NOTE:THIS PRODUCT HAS BEEN FORMULATED
    FOR OPHTHALMIC APPLICATION AND IS REGULATED BY THE FDA AS A DRUG
    PRODUCT.
Other Precautions:UNDER NORMAL CONDITIONS OF USE, THIS PRODUCT IS NOT A
    HAZARDOUS MATERIAL AS DEFINED BY THE OSHA HAZARD COMMUNICATION
    STANDARD (29 CFR 1910.1200).

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
    EXPOSURE OF CONCERN . NONE REQUIRED UNDER NORMAL CONDITIONS.
Ventilation:GENERAL MECHANICAL.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH AND DELUGE
    SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:215F,102C
Spec Gravity:1.02
Solubility in Water:SOLUBLE
Appearance and Odor:CLEAR, COLORLESS, ODORLESS LIQUID.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
    FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.