RUST-OLEUM CORP -- 111 THINNER -- 8010-00N054836
===================== Product Identification ===================== Product ID:111 THINNER MSDS Date:01/22/1990 FSC:8010 NIIN:00N054836 === Responsible Party === Company Name:RUST-OLEUM CORP Address:11 HAWTHORN PKWY City:VARNON HILLS State:IL ZIP:60061 Country:US Info Phone Num:708-367-7700 Emergency Phone Num:708-367-7700 CAGE:08882 === Contractor Identification === Company Name:RUST-OLEUM CORP Address:11 HAWTHORN PARKWAY Box:City:VERNON HILLS State:IL ZIP:60061-1583 Country:US Phone:847-367-7700 CAGE:08882 ============= Composition/Information on Ingredients ============= Ingred Name:ETHANE,1,1,1-TRICHLORO-; (1,1,1-TRICHLOROEHANE) (SARA III). LEL:7.5%. VP:100 @20C. CAS:71-55-6 RTECS #:KJ2975000 Fraction by Wt: 100% OSHA PEL:350 PPM ACGIH TLV:350 PPM/450 STEL EPA Rpt Qty:1000 LBS DOT Rpt Qty:1000 LBS Ozone Depleting Chemical:1 ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:CHLOROCARBON MATLS HAVE PRDCED SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE A SIMILAR EFT IN HUMANS. ADRENOMIMETICS (E.G. EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT FOR LIFE-SUSTAIN ING USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED TO CHLOROCARBONS . ACUTE:INHALATION:HARMFUL (EFTS OF OVEREXP) Explanation of Carcinogenicity:NOT RELEVANT. Effects of Overexposure:HLTH HAZ:IF INHALED. MAY AFFECT BRAIN/ NERVOUS SYSTEM CAUSING DIZZ, HDCH OR NAUS. RPTED OVEREXPOS MAY LEAD PROGRESSIVELY TO STAGG GAIT, CONFUSN, UNCON/COMA. CAUSES NOSE & THROAT IRRIT. SKIN/EYES:CAUSE IRRIT WHICH MAY LEAD TO DERM W/RPTD OVEREXPOS. INGEST:GI IRRIT, NAUS, VOMIT & DIARR. CHRONIC:RPTS HAVE SHOWN (SUPDAT) Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER. ======================= First Aid Measures ======================= First Aid:INHAL:REMOVE FROM EXPOSURE, RESTORE BRTHG & NOTIFY PHYS. EYES:FLUSH IMMED W/LG AMTS OF WATER FOR @ LEAST 15 MINS. NOTIFY PHYS. SKIN:WASH AFFECTED AREA W/SOAP & WATER, REMOVE CONTAMD CLTHG & WASH BEFOR E REUSE. INGEST:DO NOT INDUCE VOMIT. KEEP PERSON WARM, QUIET & GET MED ATTN. ASPIR OF THIS MATL INTO LUNGS CAN CAUSE CHEMICAL PNEUMONITIS WHICH CAN BE FATAL. ===================== Fire Fighting Measures ===================== Lower Limits:SEE ING Extinguishing Media:NOT APPLICABLE. MEDIA SUITABLE FOR SURROUNDING FIRE . Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA & FULL PROTECTIVE EQUIPMENT . WATER MAY BE USED TO COOL CLSD CNTNRS TO PVNT PRESS BUILD-UP & POSS (SUPDAT) Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE HCL & PHOSGENE . CLSD CNTNRS MAY EXPLODE WHEN EXPOSED TO EXTREME HEAT DUE TO BUILD-UP OF VAPORS. ================== Accidental Release Measures ================== Spill Release Procedures:VENTILATE AREA AND REMOVE WITH INERT ABSORBENT. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:NONFLAMM SEE OSHA 1910.106. CONT W/ALUMINUM/ GALVANIZED PARTS IN PRESSURIZABLE FLUID SYS MAY CAUSE VIOLENT REACTION. Other Precautions:CONSULT EQUIPMENT SUPPLIER FOR FURTHER INFORMATION. NO SMOKING IN AREA OF USE. DO NOT USE IN GEN VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT &/OR UV RADIA MAY CAUSE FORMATION OF HCL &/O R PHOSGENE . ============= Exposure Controls/Personal Protection ============= Respiratory Protection:USE NIOSH/MSHA APPRVD CHEMICAL CARTRIDGE RESP (TC23C) TO REMOVE SOLID AIRBORNE PARTICLES OF OVERSPRAY & ORG VAP DURING SPRAY APPLIC. IN CONFINED AREAS:USE NIOSH/MSHA APPRVD SUPPLIED-AIR RESP OR HOODS (TC19C). Ventilation:PROVIDE GEN DILUTION/LOC EXHAUST VENT IN VOL & PATTERN TO KEEP TLV HAZ INGRES BELOW ACCEPTABLE LIMITS. Protective Gloves:IMPERVIOUS GLOVES . Eye Protection:ANSI APPRVD CHEM WORKERS GOGG . Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER. Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER. Supplemental Safety and Health FIRE FIGHT PROC:AUTOIGNIT/EXPLOSION. IF WATER IS USED, FOG NOZZ ARE PREF. EFTS OF OVEREXPOS:REPEATED & PROLONGED OCCUP OVEREXPOS TO SOLVENTS W/PERMANENT BRAIN & NERVOUS SYSTEM DAMAGE. ================== Physical/Chemical Properties ================== HCC:T4 Boiling Pt:B.P. Text:165F,74C Vapor Pres:SEE ING Vapor Density:HVR/AIR Spec Gravity:1.21 Evaporation Rate & Reference:SLOWER (ETHER =1) Solubility in Water:NOT KNOWN Appearance and Odor:NONE SPECIFIED BY MANUFACTURER. Percent Volatiles by Volume:100 ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES WITH STRONG OXIDIZING AGENTS. Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER. Hazardous Decomposition Products:HCL & PHOSGENE . BY OPEN FLAME - CARBON MONOXIDE AND CARBON DIOXIDE. ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPOSE OF ACCORDING TO LOCAL, STATE AND FEDERAL REGULATIONS. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.