NATIONAL GYPSUM CO -- GOLD BOND EASY FINISH READY MIX JOINT COMPOUND -- 5640-00N080258
=====================  Product Identification  =====================

Product ID:GOLD BOND EASY FINISH READY MIX JOINT COMPOUND
MSDS Date:05/06/1994
FSC:5640
NIIN:00N080258
=== Responsible Party ===
Company Name:NATIONAL GYPSUM CO
Address:2001 REXFORD RD
City:CHARLOTTE
State:NC
ZIP:28211
Country:US
Info Phone Num:704-365-7543
Emergency Phone Num:704-365-7543
Preparer's Name:NORBERT W. KALETA
CAGE:85074
=== Contractor Identification ===
Company Name:NATIONAL GYPSUM CO
CAGE:85074
Company Name:NATIONAL GYPSUM CO
Box:UNKNOW
CAGE:87074

=============  Composition/Information on Ingredients  =============

Ingred Name:CALCIUM CARBONATE
CAS:1317-65-3
RTECS #:EV9580000
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST

Ingred Name:SILICA, CRYSTALLINE - QUARTZ
CAS:14808-60-7
RTECS #:VV7330000
OSHA PEL:N/K 
ACGIH TLV:0.1 MG/M3 RDUST

Ingred Name:SILICATE, MICA
CAS:12001-26-2
RTECS #:VV8760000
OSHA PEL:20 MPPCF
ACGIH TLV:3 MG/M3 RDUST

Ingred Name:TALC (POWDER), CONTAINING NO ASBESTOS FIBERS
CAS:14807-96-6
RTECS #:MW2700000
OSHA PEL:0.2 FIBERS/CC
ACGIH TLV:0.2 FIBER/CC

Ingred Name:PERLITE
CAS:93763-70-3
RTECS #:SD5254000
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST

Ingred Name:PALYGORSKITE; (ATTAPULGITE CLAY)
CAS:12174-11-7
RTECS #:RT6400000
OSHA PEL:N/K 
ACGIH TLV:N/K 

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:NO
Health Hazards Acute and Chronic:SKIN: CONTINUED AND PROLONGED CONTACT
    MAY CAUSE TRANSIENT IRRITATION TO SKIN. EYE: DIRECT CONTACT MAY
    CAUSE IRRITATION. INHALATION: EXPOSURE OCCURS WHEN SANDING DRIED
    PRODUCT.
Explanation of Carcinogenicity:SILICA, CRYSTALLINE-QUARTZ: IARC
    MONOGRAPHS, SUPP. VOL 68, 1997: GRP 1. NTP 7TH ANNUAL REPORT ON
    CARCINOGENS, (SUPDAT)
Effects of Overexposure:CONTINUE AND PROLONGED EXPOSURE TO AIRBORNE
    DUST CONCENTRATIONS IN EXCESS OF PEL/TLV MAY RESULT IN COUGH,
    DYSPNEA, WHEEZING AND IMPAIRED PULMONARY FUNCTION.
Medical Cond Aggravated by Exposure:OVEREXPOSURE WOULD GENERALLY
    AGGRAVATE RESPIRATORY SYSTEM DYSFUNCTIONS.

=======================  First Aid Measures  =======================

First Aid:EYE: IMMEDIATELY FLUSH WITH WATER FOR AT LEAST 15 MINUTES AND
    GET MEDICAL ATTENTION. SKIN: FLUSH AND WASH WITH SOAP AND WATER.
    GET MEDICAL ATTENTION IF IRRITATION PERSISTS. INHALATION: MOVE
    EXPOSED PE RSON TO FRESH AIR AT ONCE. IF NOT BREATHING INITIATE
    PULMONARY RESUSCITATION. GET MEDICAL ATTENTION. INGESTION: CALL MD
    IMMEDIATELY .

=====================  Fire Fighting Measures  =====================

Extinguishing Media:DRY CHEMICAL, FOAM, WATER FOG OR SPRAY.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
    EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

==================  Accidental Release Measures  ==================

Spill Release Procedures:SHOVEL OR SCOOP UP BACK INTO CONTAINER FOR USE
    IF POSSIBLE OR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP FROM FREEZING TO PRESERVE
    USEFULNESS.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH APPROVED RESPIRATOR FOR TOXIC DUSTS IS
    RECOMMENDED IF PEL/TLV IS EXCEEDED.
Ventilation:PROVIDE VENTILATION TO MAINTAIN DUST LEVEL BELOW PEL/TLV.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:AVOID CREATING DUST.
Supplemental Safety and Health
EXPLANATION OF CARCINOGEN: 1994: ANTICIPATED TO BE CARCINOGEN.

==================  Physical/Chemical Properties  ==================

Appearance and Odor:WHITE PASTE WITH NO ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:WHEN HEATED TO DECOMPOSITION OXIDES OF
    CARBON WILL BE RELEASED.

====================  Disposal Considerations  ====================

Waste Disposal Methods:NOT A HAZARDOUS WASTE. DISPOSE OF IN ACCORDANCE
    WITH APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.