FISHER SCIENTIFIC CO CHEMICAL DIV. -- ISOPROPYL ALCOHOL -- 6810-01-275-1252
=====================  Product Identification  =====================

Product ID:ISOPROPYL ALCOHOL
MSDS Date:01/17/1989
FSC:6810
NIIN:01-275-1252
=== Responsible Party ===
Company Name:FISHER SCIENTIFIC CO CHEMICAL DIV.
Address:1 REAGENT LANE
City:FAIR LAWN
State:NJ
ZIP:07410
Country:US
Info Phone Num:201-796-7100
Emergency Phone Num:201-796-7100 OR 201-796-7523
CAGE:1B464
=== Contractor Identification ===
Company Name:FISHER SCIENTIFIC CO.  CHEMICAL MFG DIV
Address:1 REAGENT LANE
Box:City:FAIRLAWN
State:NJ
ZIP:07410-2802
Country:US
Phone:201-796-7100
CAGE:1B464

=============  Composition/Information on Ingredients  =============

Ingred Name:ISOPROPYL ALCOHOL  (SARA III)
CAS:67-63-0
RTECS #:NT8050000
Fraction by Wt: 100%
Other REC Limits:NONE SPECIFIED
OSHA PEL:400 PPM/500 STEL
ACGIH TLV:400 PPM/500STEL;9192

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:ORAL LD50 (RAT) = 5045 MG/KG
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: OVEREXPOSURE MAY LEAD TO CNS
    DEPRESSION, LEADING TO HEADACHES AND DIZZINESS. EYE: MAY LEAD TO
    IRRITATION AND WILL INJURE EYE TISSUE IF NOT REMOVED PROMPTLY.
    SKIN: NO HEALTH HAZARD FROM ABSORPTI ON OR EXPOSURE. INGESTION:
    SLIGHT HEALTHHAZARD. CHRONIC: PROLONGED EXPOSURE CAN BE IRRITATING
    TO MUCOUS MEMBRANES.
Explanation of Carcinogenicity:THIS CHEMICAL IS NOT LISTED AS HAVING
    ANY EVIDENCE OF BEING CARCINOGENIC.
Effects of Overexposure:OVEREXPOSURE MAY LEAD TO DIZZINESS, SHORTNESS
    OF BREATH, HEADACHES, VOMITING, DERMATITIS AND EYE IRRITATION
    (BURNING AND TEARING). HIGH VAPOR CONCENTRATIONS ARE ANESTHETIC AND
    MAY HAVE OTHER CENTRAL N ERVOUS SYSTEM EFFECTS. CHRONIC SKIN
    EXPOSURE MAY LEAD TO DEFATTING OF TISSUE AND DERMATITIS.
Medical Cond Aggravated by Exposure:PERSONS WITH EYE, SKIN, HEART,
    RESPIRATORY, OR ANY OTHER MEDICAL CONDITION SHOULD USE CAUTION WHEN
    HANDLING OR USING THIS PRODUCT.

=======================  First Aid Measures  =======================

First Aid:SKIN: REMOVE CONTAMINATED CLOTHING. WASH WITH SOAP AND WATER.
    GET MEDICAL ATTENTION AS REQUIRED. INHALATION: IMMEDIATELY REMOVE
    VICTIM TO FRESH AIR. GIVE OXYGEN OR ARTIFICIAL RESPIRATION AS
    NEEDED. GE T PROMPT MEDICAL ATTENTION. EYE: IMMEDIATELY FLUSH WITH
    WATER FOR 20 MINUTES WITH EYELIDS HELD OPEN. GET PROMPT MEDICAL
    ATTENTION. INGESTION: GET PROMPT MEDICAL ATTENTION. DO NOT INDUCE
    VOMITING.

=====================  Fire Fighting Measures  =====================

Flash Point Method:CC
Flash Point:53.0F,11.7C
Lower Limits:2
Upper Limits:12.7
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM, OR DRY
    CHEMICAL.  DO NOT USE A DIRECT STREAM OF WATER.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
    FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
    SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:FIRE OR EXCESSIVE HEAT MAY CAUSE
    PRODUCTION OF HAZARDOUS DECOMPOSITION PRODUCTS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:FIRE HAZARD: ELIMINATE ALL SOURCES OF
    IGNITION. EVACUATE AREA. VENTILATE AREA. STOP RELEASE. DIKE TO
    CONTAIN SPILL. WEAR PROPER SAFETY EQUIPMENT. IF AMOUNT IS LARGE,
    REMOVE LIQUID BY VACUUM. IF SMALL,	ABSORB ON INERT MATERIAL.
    DISPERSE RESIDUE.
Neutralizing Agent:DILUTE WITH WATER

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN TIGHTLY CLOSED CONTAINERS
    AWAY FROM HEAT, SPARKS, OPEN FLAME & STRONG OXIDIZING AGENTS. EMPTY
    CONTAINERS MAY CONTAIN FLAMMABLE VAPOR.
Other Precautions:DO NOT PRESSURIZE, CUT, WELD, BRAZE, SOLDER, DRILL,
    GRIND, OR EXPOSE CONTAINERS TO HEAT, FLAME, SPARKS, STATIC
    ELECTRICITY, OR OTHER SOURCES OF IGNITION. MATERIAL MAY ATTACK SOME
    FORMS OF PLASTIC, ALU MINUM, RUBBER AND COATINGS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE NIOSH/MSHA APPROVED AIR-PURIFYING OR
    SUPPLIED AIR RESPIRATOR AS APPROPRIATE.
Ventilation:MECHANICAL(GENERAL) EXHAUST RECOMMENDED. LOCAL OR EXPLOSION
    PROOF VENTILATION MAY BE REQUIRED IN SOME CIRCUMSTANCES.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:CHEMICAL SPLASH GOGGLES &/OR FACESHIELD
Other Protective Equipment:EYE WASH STATION & SAFETY SHOWERS SHOULD BE
    AVAILABLE IN THE IMMEDIATE VICINITY OF ANY POTENTIAL EXPOSURE.
Work Hygienic Practices:WASH HANDS BEFORE EATING, DRINKING, SMOKING, OR
    USING TOILET FACILITIES. WASH CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
AVOID VOMITING IN CASES OF OVEREXPOSURE SINCE ASPIRATION INTO LUNGS IS
    A POSSIBLE HAZARD. PROPERLY GROUND LARGER DRUMS OF MATERIAL TO
    GUARD AGAINST STATIC ELECTRICITY.  PRACTICE GOOD HOUSEKEEPING.  PO
    ST NO-SMOKING SIGNS.  NOTIFY THE NATIONAL RESPONSE CENTER IN CASE
    OF SPILLS.

==================  Physical/Chemical Properties  ==================

HCC:F2
Boiling Pt:B.P. Text:180F,82C
Melt/Freeze Pt:M.P/F.P Text:-129F,-89C
Vapor Pres:40 @24C
Vapor Density:2.1
Spec Gravity:0.785
Solubility in Water:COMPLETE
Appearance and Odor:TRANSPARENT, COLORLESS, MOBILE LIQUID WITH A
    CHARACTERISTIC MILD ALCOHOLIC ODOR

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, ALUMINUM, BARIUM PERCHLORATE, OLEUM, PHOSGENE,
    PLASTICS AND RUBBER (MAY BE DEGRADED).
Stability Condition to Avoid:HIGH TEMPERATURES, SPARKS, AND OPEN FLAMES
Hazardous Decomposition Products:INCOMPLETE COMBUSTION MY YIELD CARBON
    MONOXIDE AND OTHER TOXIC GASES

====================  Disposal Considerations  ====================

Waste Disposal Methods:UNUSED MATERIALS WILL BE A LAND-BANNED HAZARDOUS
    WASTE.  TREAT/RECYCLE MATERIAL IN ACCORDANCE WITH ALL APPLICABLE
    REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.